TECHNICAL DATA | |
---|---|
Supply voltage | ~230V |
Maximum load | 3 x 100VA |
CH pump start temperature | 20 - 80°C |
TW pump start temperature | 20 - 70°C |
Boiler temp. regulation range | 25 - 90°C |
Temperature of the TW container | 30 - 80°C |
TW container hysteresis | 1 - 15°C |
Blower hysteresis | 0,5 - 5°C |
CH pump hysteresis | 1 - 15°C |
“Anti-stop” function | every 14day/30s |
Blow adjustable time and frequency | |
Blower power control |
optional color
Microprocessor controller MTS 10z is a unit to control CH pump, feeding pump for TW container and a blow in boiler. Protects the container and heaters against cooling down if the boiler is too cold. It can work in WINTER or SUMMER mode. Controller is adjusted to work with a room sensor. Instead of this factory-delivered room sensor, MTS 10z can work with a thermostat (wire or wireless). Controller works with ”anti-stop” function. It can work with priority of warm tap water. MTS 10z has a thermal breaker as additional protection to reduce a risk of the boiler overheating.